Side exit, high temp 260°C, high frequency 20 mV/g sensor & charge amplifier system w/ 16' J3 integral cable, case isolated, ATEX certified for use in Zone 0 and Zone 1 hazardous areas
PARAMETER | VALUE |
---|---|
Sensor output | Dynamic vibration (IEPE) |
Sensitivity | 20 mV/g |
Sensitivity tolerance | ±10 % |
Frequency response | 0.5 Hz - 20,000 Hz |
Mounting Thread | 8-32 captive screw |
Connector style | Integral cable |
Connector orientation | Side exit |
Full-scale range | 100 g peak |
Resonance frequency | 37.5 Khz |
Temperature range | -50°C to +260°C |
Weight | 40 g (712E excluding cable); 123 g (CC712E) |
Hazardous area approvals | ATEX Ga Ex ia |