Phone: +1-301-330-88111-800-WILCOXON
Model 746
Underwater accelerometer, 100 mV/g sensitivity, titanium case for long term reliability in submerged monitoring locations, 10ft integral J6 cable, case isolated
PARAMETER | VALUE |
---|---|
Sensor output | Dynamic vibration (IEPE) |
Sensitivity | 100 mV/g |
Sensitivity tolerance | ±5 % |
Frequency response, ±3 dB | 1 Hz - 15,000 Hz |
Mounting thread | 10-32 tapped hole |
Connector style | Integral cable |
Connector orientation | Top exit |
Full-scale range | 80 g peak |
Resonance frequency | 30 kHz |
Temperature range | –50°C to +80°C |
Weight | 45 grams |
Hazardous area approvals | Non-approved |