Phone: +1-301-330-88111-800-WILCOXON
Accelerometer, hazardous area certified, 100 mV/g sensitivity, low profile with side exit 4-pin M12 connector, case isolated, API 670 compliant, certified for use in Class I Division 2 and Zone 2 hazardous locations

| PARAMETER | VALUE |
|---|---|
| Sensor output | Dynamic vibration (IEPE) |
| Sensitivity | 100 mV/g |
| Sensitivity tolerance | ±5 % |
| Frequency response, ±3 dB | 0.5 Hz - 10,000 Hz |
| Mounting thread | M6 captive screw |
| Connector style | M12, 4-pin |
| Connector orientation | Side exit |
| Full-scale range | 80 g peak |
| Resonance frequency | 22 kHz |
| Temperature range | -50°C to +120°C |
| Weight | 145 grams |
| Hazardous area approvals | Class I, Div 2, Zone 2; ATEX II 3G Ex nA |