Phone: +1-301-330-88111-800-WILCOXON

Intrinsically Safe accelerometer with high temperature integral cable, low profile, 100 mV/g

Model 787F-IM-IS

General purpose accelerometer, 100 mV/g sensitivity, ±5% sensitivity tolerance, low profile with side exit over-molded integral cable, 16 ft. J9T2A Teflon jacketed cable rated to 200°C, case grounded, internally shielded, certified for use in Class I Division 1 and ATEX Zone 0/1 hazardous areas

Integral cable accelerometer features

  • Injection molded integral cable design reduces price and improves durability
  • Certified Intrinsically Safe (IS) for Class I Div 1 hazardous locations
  • ATEX and IECEx Zone 0/1 certification for global hazardous area compliance
  • Hermetically sealed 316L stainless steel sensor body
  • IP68 molded cable exit for enhanced environmental protection
  • 100 mV/g IEPE output general purpose accelerometer
  • Wide operating temperature range: –50°C to +120°C
  • J9T2A twisted, shielded pair cable with yellow Teflon jacket (200°C rating), 16 ft standard, blunt cut, side exit for low profile

The 787F-IM-IS is a low-profile Intrinsically Safe IEPE accelerometer designed for dependable vibration monitoring in hazardous locations. Built using Wilcoxon’s injection molded integral cable process, the J9T2A cable is permanently overmolded to the hermetically sealed 316L stainless steel sensor housing, reducing price, shortening lead times, and eliminating traditional cable transition points that can contribute to mechanical failure.

Certified to CSA, ATEX, and IECEx standards, this Intrinsically Safe vibration sensor delivers reliable performance on rotating machinery and other critical assets operating in explosive atmospheres.

Included accessories

  • 1/4-28 captive hex head screw

Specifications

PARAMETER VALUE
Sensor output Dynamic vibration (IEPE)
Sensitivity 100 mV/g
Sensitivity tolerance ±5 %
Frequency response, ±3dB 0.5 Hz - 10,000 Hz
Mounting thread 1/4-28 captive hex head screw
with 0.046" diameter safety wire hole
Connector style Rugged, over-molded integral cable
Connector orientation Side exit
Full-scale range 80 g peak
Resonance frequency 22 kHz
Temperature range -50°C to +120°C
Weight 145 grams
Hazardous area approvals CSA: Intrinsically Safe, Class I Div 1
ATEX and IECEx: Zone 0/1