Phone: +1-301-330-88111-800-WILCOXON
Accelerometer, radiation resistant (1x107 RADs exposure limit), 100 mV/g sensitivity, ±5% sensitivity tolerance, top exit MIL-C-5015-style connector, case isolated
Accelerometers, cable assemblies, and mounting accessories with radiation resistance up to 1x107 RADs make vibration monitoring possible on critical machines in nuclear power plants. The 793R high performance accelerometer is suitable for gearboxes and other vibration monitoring applications that benefit from high frequency analysis.
PARAMETER | VALUE |
---|---|
Sensor output | Dynamic vibration (IEPE) |
Sensitivity | 100 mV/g |
Sensitivity tolerance | ±5 % |
Frequency response, ±3 dB | 1 Hz - 15,000 Hz |
Mounting thread | 1/4-28 tapped hole |
Connector style | MIL-C-5015, 2-pin |
Connector orientation | Top exit |
Full-scale range | 50 g peak |
Resonance frequency | 26 kHz |
Temperature range | -50°C to +120°C |
Weight | 110 grams |
Hazardous area approvals | Non-approved |