Phone: +1-301-330-88111-800-WILCOXON
Certification update: CSA certification is being updated, and shipments are on hold. ATEX and IECEx approvals are not affected. Please contact us to discuss your order, application or lead time.
Intrinsically safe vibration transmitter, 4-20 mA output proportional to peak velocity vibration, 2.0 in/sec full-scale measurement range, ±5% tolerance at full scale, operates up to 85°C, top exit 2-pin MIL-C-5015 style connector, certified for use in Class I Division 1 and Zone 0 / Zone 1 hazardous locations

| PARAMETER | VALUE |
|---|---|
| Sensor output | 4-20 mA |
| Measurement unit | Velocity |
| Detector type | Peak |
| Full-scale range | 2 IPS |
| Frequency response, ±3dB | 4 Hz - 2,000 Hz |
| Connector style | MIL-C-5015, 2-pin |
| Connector orientation | Top exit |
| Temperature range | -40°C to +85°C |
| Weight | 162 grams |
| Hazardous area approvals | ATEX: II 1 G; ATEX / IECEx: Ex ia IIC T4 Ga, -40°C ≤ Ta ≤ +85°C |