Phone: +1-301-330-88111-800-WILCOXON

Intrinsically Safe accelerometer with high temperature integral cable, 100 mV/g

Model 786F-IM-IS

General purpose accelerometer, 100 mV/g sensitivity, ±5% sensitivity tolerance, top exit integral cable, 16 ft. J9T2A Teflon jacketed cable rated to 200°C, case isolated, internally shielded, certified for use in Class I Division 1 and ATEX Zone 0/1 hazardous areas

Downloads

Integral cable accelerometer features

  • Injection molded integral cable design reduces price and improves durability
  • Certified Intrinsically Safe (IS) for Class I Div 1 hazardous locations
  • ATEX and IECEx Zone 0/1 certification for global hazardous area compliance
  • Hermetically sealed 316L stainless steel sensor body
  • IP68 molded cable exit for enhanced environmental protection
  • 100 mV/g IEPE output general purpose accelerometer
  • Wide operating temperature range: –50°C to +120°C
  • J9T2A twisted, shielded pair cable with yellow Teflon jacket (200°C rating), 16 ft standard, blunt cut

The 786F-IM-IS is a rugged Intrinsically Safe IEPE accelerometer designed for dependable vibration monitoring in hazardous locations. Built using Wilcoxon’s injection molded integral cable process, the J9T2A cable is permanently over-molded to the hermetically sealed 316L stainless steel sensor housing, reducing price, shortening lead times, and eliminating traditional cable transition points that can contribute to mechanical failure.

Certified to CSA, ATEX, and IECEx standards, this Intrinsically Safe vibration sensor delivers reliable performance on rotating machinery and other critical assets operating in hazardous atmospheres.

Included accessories

  • SF6 mounting stud

Specifications

PARAMETER VALUE
Sensor output Dynamic vibration (IEPE)
Sensitivity 100 mV/g
Sensitivity tolerance ±5 %
Frequency response, ±3 dB 0.5 Hz - 13,000 Hz
Mounting thread 1/4-28 UNF tapped hole
Connector style Integral cable, rugged over-mold
Connector orientation Top exit
Full-scale range 80 g peak
Resonance frequency 30 kHz
Temperature range -50°C to +120°C
Weight 90 grams (excluding cable)
Hazardous area approvals CSA: Intrinsically Safe, Class I Div 1
ATEX and IECEx: Zone 0/1

We are using cookies to give you the best experience on our website. Our Privacy Policy has been updated.
You can find out more about which cookies we are using or switch them off by changing your browser settings.

Accept All